Eo - echo mode – ElmoMC SimplIQ Command Reference User Manual

Page 62

Advertising
background image

EO - Echo Mode

Purpose:
Sets or resets the communication echo mode, which is used for communication checks.
ƒ

EO=1 enables echo mode

ƒ

EO=0 disables it.

With RS-232 communication, the EO command sends an immediate echo character for
every terminal character. The echo transmission is deferred to the command response
string.

Attributes:

Type: Parameter,

Integer

Source: RS-232
Restrictions: None
Default value: 1,

Volatile

Range: [0,

1]

Unit modes: All
Activation: Immediate


Note: Once the EO setting has been changed with a Terminal Program to EO=0, no
communication is possible over Composer.

SimplIQ

Command Reference Manual

Alphabetical Listing

MAN-SIMCR (Ver. 4.5)

3-49

Advertising