ElmoMC SimplIQ Command Reference User Manual

Page 38

Advertising
background image

Notes:

ƒ

The motor stuck protection is always applied to the main sensor. In dual loop
applications, this protection does not pertain to failures in the auxiliary sensor.

ƒ

The time constant of 3 seconds is taken because almost every motion system
applies high torques for short acceleration periods while the speed is slow.

ƒ

The minimum current limit is MC/128. If CL[1] < MC/128, the CL[1] value will be
accepted, but the actual current value will be limited to MC/128.

See also:

LC

,

MC

,

PL[N]

,

TC

,

MF

Reference chapters in The SimplIQ Software Manual:
Chapter 10, ”The Current Controller;” Chapter 14, “Limits, Protection, Faults and
Diagnosis”

SimplIQ

Command Reference Manual

Alphabetical Listing

MAN-SIMCR (Ver. 4.5)

3-25