“8” – indicates an unexpected error during an absolute position inquire. Verify

hardware connection of the absolute feedback type.

Attributes:

Type:

Status report, String

Source: RS-232
Restrictions: None
Unit modes:

All

Notes:

ƒ

If an LD command fails, CD reports the reason for the failure by adding the string
“Couldn’t load from serial flash” followed by the reason for the failure.

ƒ

The 3-second time constant is used because almost every motion system applies
high torques for short acceleration periods at low speeds.

ƒ

The minimum current limit is MC/128. If CL[1] < MC/128, the CL[1] value will be
accepted, but the actual current value will be limited to MC/128.

Example:
Null Address=0
Failure Address=0
Called Handler=none
Database Status:
CA[4], error code=37

This CD report indicates that the database is inconsistent because two of the parameters
CA[4], CA[5] and CA[6] are equal.

See also:

MF

,

SR

,

MO

,

EC

SimplIQ

Command Reference Manual

Alphabetical Listing

MAN-SIMCR (Ver. 4.5)