ElmoMC SimplIQ Command Reference User Manual

Page 51

Advertising
background image

Error
Code


Error String / Description


Example / Remedy

90

CAN state machine is not ready (object
0x6041 on DS402).

Set the drive to the “Switched
on” state machine by setting the
relevant transitions to the control
word, object 0x6040. Refer to the
description of NMT services in
the Elmo CANopen Implemen-
tation manual.

93

There is a wrong initiation value for this
command.

Reset queue length before
updating queries.

95

Too large for modulo setting.

The modulo range is inconsistent
with the ER[3] value. Refer to the

ER[N]

command.

96

User program time out.
Execution of a single user program line was
more than expected (more than 3 seconds).
The SimplIQ drives stops program
execution.

97

RS232 receive buffer overflow.
Characters arrived through RS-232 at too
high a rate, causing internal storage to
exceed its capacity. No more space is left to
store new characters.

99

The auxiliary feedback entry does not
configure as output during the activation of
Output Compare

100

The requested PWM value is not supported The PWM frequency that was

requested cannot be used with
the drive.

101

Abortive attempt to read a position value
from the absolute position sensor. CD
command also indicates failure details.

105

Speed loop KP out of range.
Value of KP[2] or one of KG[64]…KG[126]
is out of numeric range.

106

Position loop KP out of range.
Value of KP[3] or one of KG[127]…KG[189]
is out of numeric range.

SimplIQ

Command Reference Manual

Alphabetical Listing

MAN-SIMCR (Ver. 4.5)

3-38