ElmoMC SimplIQ Command Reference User Manual

Page 83

Advertising
background image


Command Value Active Level

When Active . . .

IL[N]=0

Low

Shut servo drive, freewheel.

IL[N]=1

High

Shut servo drive, freewheel
Note: It is high recommended not to use this state.
The motor may spin when the input wire is cut or
disconnected.

IL[N]=2

Low

Stop immediately under control: soft and auxiliary
stop.

IL[N]=3

High

Stop immediately under control: soft and auxiliary
stop.

IL[N]=4 Low No

function

is

attached. Ignore the switch.

IL[N]=5 High No

function

is

attached. Ignore the switch.

IL[N]=6

Low

General purpose.

IL[N]=7 High General

purpose.

IL[N]=8

Low

Hard-enable forward direction only (RLS).

IL[N]=9

High

Hard-enable forward direction only (RLS).

IL[N]=10 Low Hard-enable

reverse direction only (FLS).

IL[N]=11 High Hard-enable

reverse direction only (FLS).

IL[N]=12

Low

Begin: activates BG command.

IL[N]=13 High Begin:

activates BG command.

IL[N]=14 Low Stop

immediately

under control: soft stop only.

Activates the ST command.

IL[N]=15 High Stop

immediately

under control: soft stop only.

Activates the ST command.

IL[5]=16

Low

Enable the Main Home sequence.

IL[5]=17 High Enable

the Main Home sequence.

IL[6]=18

Low

Enable the Auxiliary Home sequence.

IL[6]=19

High

Enable the Auxiliary Home sequence.

IL[N]=20 Low Stop

immediately

under control: stop both software

trajectory and auxiliary reference.

IL[N]=21 High Stop

immediately

under control: stop both software

trajectory and auxiliary reference.

IL[N]=22

Low

Abort motion. Shut servo drive, freewheel.

IL[N]=23 High Abort

motion.

Shut servo drive, freewheel.

Table 3-19: Possible Values for IL[N]

SimplIQ

Command Reference Manual

Alphabetical Listing

MAN-SIMCR (Ver. 4.5)

3-70

Advertising