Error
Code


Error String / Description


Example / Remedy

111

KV[N] vector is invalid.
Invalid values in KV[N] parameters.

Refer to the “Advanced Filter”
chapter in the

SimplIQ

Software

Manual. If the vector was
configured by the Composer
auto-tuning wizard, email
Technical Support for assistance.

112

KV[N] defines scheduled block but
scheduling is off.
Invalid values in KV[N] parameters.

See the syntax of KV[N]
parameters in the “Advanced
Filter” chapter of the

SimplIQ

Software Manual. If the vector was
configured by the Composer
auto-tuning wizard, email
Technical Support for assistance.

113

Exp task queue is full.
Internal error during auto-tuning process.

114

Exp task queue is empty.
Internal error during auto-tuning process.

115

Exp output queue is full.
Internal error during auto-tuning process.

116

Exp output queue is empty.
Internal error during auto-tuning process.

117

Bad KV setting for sensor filter.
Invalid setting for KV[76]…KV[87].

See

KV

command section of this

manual.

118

Bad KV vector

This can happen when KV
parameters are not set according
to the correct feedback with
either length or value restriction.

119

Bad Analog sensor Filter

When the filter KV, set for analog
feedback, is beyond its legal
range.

120

Bad number of blocks for Analog sensor
filter

When the analog sensor filter
contains a wrong number of
blocks.

121

Analog sensor is not ready

When the initiation procedure of
the Analog sensor was not
completed, and the motor is
being enabled.

SimplIQ

Command Reference Manual

Alphabetical Listing

MAN-SIMCR (Ver. 4.5)

3-39

Advertising