Simpliq – ElmoMC SimplIQ Command Reference User Manual
Page 105
Notes:
MI is not affected by the XQ command. You should set MI to the desired value in
the first lines of your user program in order to ensure that the correct automatic
routines can run.
Several interrupts may be blocked by the MI command. MI=65,535 or MI=0xffff
will block all interrupts of the table. MI=48 will block only the AUTO_FLS and the
AUTO_RLS interrupts. MI=MI|2 will block AUTO_ER and leave all other
interrupt mask bits as is.
If AUTO_PERR is activated, all other interrupts will be masked (MI=0x7fff).
Attributes:
Type: Parameter,
Integer,
Bit-field
Scope:
Program, RS-232, CANopen
Restrictions: None
Default values: 0,
Volatile
Range: [0…65,535]
Unit modes: All
Activation: Immediate
See also:
XQ
,
XC
Reference chapter in the
SimplIQ
Software Manual:
Chapter 5, ” The
SimplIQ
User Programming Language”
SimplIQ
Command Reference Manual
Alphabetical Listing
MAN-SIMCR (Ver. 4.5)
3-92