HX - Hexadecimal Mode

Purpose:
Sets or resets the hexadecimal mode for reporting integer parameter values.
ƒ

With HX=0, integers are reported as decimal numbers.

ƒ

With HX=1, integers are reported as hexadecimal numbers.

HX does not affect floating-point reports.

The HX parameter allows easy reading of the digital inputs (IP), servo drive status (SR),
motor faults (MF), recorder settings (RC) and other variables that have the bit-field
attribute.

The HX parameter is not required for setting values. The commands BH=1024 and
BH=0x400 are equivalent, as 0x400 equals its decimal equivalent 1024.

Attributes:

Type: Parameter,

Integer

Source: RS-232

Restrictions: None
Default value: 0,

Volatile

Range: [0,

1]

Unit modes: All
Activation: Immediate