ElmoMC SimplIQ Command Reference User Manual

Page 140

Advertising
background image

RP[N] Range

Definition

RP[4]: Level 1

Unlimited Level for positive slope trigger, or high side for

window trigger.

RP[5]: Level 2

Unlimited

Level for negative slope trigger, or low side for
window trigger.

RP[6]: Polarity

[0…63]

Defines the polarity for the digital input trigger of
the recorder.
1: Positive polarity.

RP[7]: Digital
input mask

[0…63]

Defines which digital inputs trigger the recorder.

Table 3-41: Trigger-related RP[N] Parameters

The following parameters enable the BH command to fetch only the required part of the
recorder results:

RP[N] Range

Definition

RP[8]: Index low

[0…1024]

Lower buffer index for recorded data
transmission.

RP[9]: Index high

[0…1024]

Higher buffer index for recorded data trans-
mission. When RP[9]=RP[8]=0, all of the buffer is
transmitted.

Table 3-42: RP[N] Parameters Related to the BH command

Attributes:

Type: Parameter,

Integer

Source:

Program, RS-232, CANopen

Restrictions: None
Default values:

RP[1] is set by the UM command. The other

RP[N] values are defaulted to 0 at power on

Range:

Defined in previous tables

Index range: [1…9]
Unit modes: All
Activation: Trigger

parameters: RR=3

Upload

parameters:

Immediate

If the drive has stored a previously recorded data vector, setting RP[N] (with N

other than 8 or 9) will invalidate this data. Invalidated data cannot be retrieved.

See also:

RC

,

RG

,

RL

,

RR

,

BH

Reference chapter in the

SimplIQ

Software Manual:

Chapter 7.4, “The Recorder”

SimplIQ

Command Reference Manual

Alphabetical Listing

MAN-SIMCR (Ver. 4.5)

3-127