PM - Profiler Mode

Purpose:
Specifies, in UM=2, if the software speed command generator applies acceleration,
deceleration and smoothing limits.

The values of PM are outlined in the following table:

PM Value Description

0

For UM=2, AC, DC and SF are not used.

1

For UM=2, AC, DC and SF are used normally.

Table 3-36: PM Values

PM=0 is set by the Composer program to test the step response of the speed controller.
Even with PM=0, the speed command acceleration and deceleration is limited by the SD
parameter.

PM=1 is the recommended value for all applications.

Attributes:

Type: Command/Parameter,

Integer

Source:

Program, RS-232, CANopen

Restrictions: MO=0
Default value: 1,

Non-volatile

Range: [0,

1]

Unit modes: UM=2
Activation: MO=1

See also:

UM

,

AC

,

DC

,

SD

,

SF

Reference chapters in the

SimplIQ

Software Manual:

Chapter 11, ”Unit Modes;” Chapter 12, “The Position Reference Generator”

SimplIQ

Command Reference Manual

Alphabetical Listing

MAN-SIMCR (Ver. 4.5)