PR 5220 Instrument Manual

Ethernet Transmitter Series

Sartorius

EN-11

2.2

Overview of the Instrument

-

Accuracy 10,000 e @ 6 samples/sec

-

Internal resolution: 7.5 million counts

-

Linearity: < 0.002%

-

Sampling rate: 6 ... 100/sec selectable

-

Digital filter with selectable characteristic

-

Electrically isolated interfaces

-

3 programmable pairs of limit values

-

24 VDC supply voltage connection

-

Connection using plug-in terminal blocks

-

Socket for LAN adaptor

-

The instrument is provided for snap-on mounting on a standard
rail.

-

5 status LEDs für supply voltage, communication, error detection

Calibration and configuration of the instrument are menu guided using a PC.

-

Calibration with weight, using the mV/V method or with load cell
data (“smart calibration”)

-

0/4 ... 20 mA analog output, configurable for gross/net weight

-

Analog value via fieldbus

-

3 digital input channels, electrically isolated

-

3 digital output channels, electrically isolated

Communication protocols
For the internal RS-485:

-

Remote display protocol

-

SMA protocol

-

xBPI protocol

For the internal LAN:

-

ModBus-TCP

-

Ethernet-TCP/IP

-

OPC

Fieldbus slave:

-

PR 5220/01 ProfiBus-DP

-

PR 5220/04 DeviceNet

-

PR 5220/06 ProfiNet I/O

-

PR 5220/07 EtherNet-IP