3.1.10

ProfiBus Interface (PR 5220/01 only)

Communication protocols and syntax comply with the ProfiBus-DP standard to IEC 61158 with transfer rates
up to 12 Mbit/s.

Transfer rate

9.6 kbit/s to 12 Mbit/s,
baud rate auto-detection

Protocol

PR OFIBUS-DP-V0 slave
to EN 50 170 (DIN 19245),
mono or multi-master systems are
supported. Master and slave devices,
max. 126 nodes possible.
Watchdog timer

Configuration

GSD file (‚SART5220.gsd’ stored on the
CD in directory ‘Fieldbus’)

Cable

Special ProfiBus color: violet
Shielded twisted pair cable

Cable impedance

150 ¥

Certificates

ProfiBus test center Comdec in
Germany and PNO (ProfiBus User
Organization).
Suitable for industrial applications to
CE, UL and cUL

Electrical isolation Optocoupler in lines A and B (RS-485)
Cable length

Max. distances 200 m can be extended
with 1.5 Mbit/s by means of additional
repeater


Connection to the ProfiBus is using the 9-contact plug-in socket on the front panel.

The transmitter is the only
or last slave on the bus

The transmitter is not the only
or last slave on the bus

PIN

Signal

3
4
5
6

8

RxD/TxD-P
CNTR-P
DGND
VP

RxD/TxD-P