Pr 5220 instrument manual j-bus/modbus protocol – Rice Lake PR5220 Ethernet Transmitter User Manual

Page 121

Advertising
background image

PR 5220 Instrument Manual

J-Bus/ModBus Protocol

Sartorius

EN-121

Function 5: Writing a Bit

Command

Device
address

Function
number

Address of
the bit

Value of
the bit

Always 0

1 byte

1 byte

2 bytes

1 byte

1 byte

Range

0...127

5

0...127

0 or 255

0


Reply

Device
address

Function
number

Address of
the bit

Value of
the bit

Always 0

1 byte

1 byte

2 bytes

1 byte

1 byte

If the address of the bit is out of the permissible range (0...127), an error message is sent as a reply.

Example of function 5 for setting bit 113 (taring) with ModBus-TCP:
Command

47

13

0

0

0

6

0

5

0

113

255

0

Reply

47

13

0

0

0

6

0

5

0

113

255

The individual bytes are shown.

Function 6: Writing a Word

Command

Device address Function

number

Word address Value of the

word

1 byte

1 byte

2 bytes

2 bytes

Range

0...127

6

0...63


Reply

Device address Function

number

Word address Value of the

word

1 byte

1 byte

2 bytes

2 bytes

If the address is out of the permissible range (0...63), an error message is sent as a reply.

Advertising