4.3.8.3

Weighingpoint ‚ Pendeo Load Cells’

- Search

Search load cells
-

Search for a new network and reset the load cell data to the factory

settings.

-

Or replace a single faulty load cell with the existing data.

- View

Serial number and current weigh of connected load cells are displayed.

- Info

Data of selected load cell are displayed.

- Assign

Load cells (serial number) are assigned to the mounting place.

- Calib

Calibration xBPI load cells

- New

Corner correction will be reset

Yes, No

- Number of vessel feet

Enter number of vessel feet

- Local gravity

Enter local gravity (Default: Hamburg 9,81379 m/s

2

)

- Max

Max. capacity: 0.000010 ...<3000>... 9999998 <kg>, t, lb, g, mg, oz

- Sccale interval

<1>, 2, 5, 10, 20, 50

- Dead load

Empty scale

- CAL weight

Calibration weight: 0.000010 ... 9999998 <kg>, t, lb, g, mg, oz

- Corner correction

O.k., when realized

- Modify

For minor modifications/ subsequent dead load setting only, otherwise,

use [New].

siehe ‚New‘

- Param

- Ambient conditions

Very stable, stable, unstable, very unstable

- W

& M

<none>, OIML, NSC, NTEP

- Standstill time

0.01 s…<0.50 s> ... 2.0 s

(The range depends on the measurement time.)

- Standstill range

0.00 d ... <1.00 d> ... 10.00 d

(The range depends on the measurement time.)

- Tare timeout

0.1 s ... <2.5 s> ... 25 s, timeout when there is no standstill

- Zeroset range

0.00 d ... <50.00 d> ... 10000.00 d

- Zerotrack range

0.00 d ... <0.25 d> ... 10000.00 d

- Zerotrack step

0.00 d ... <0.25 d> ... 10.00 d

- Zerotrack time

<0.0 s> ... 25 s

- Overload

0 d ... <9 d> ... 999900 d

- Min

0 d ... <50 d> ... 999900 d, min. weight

- Range mode

<Single range>, Multiple range, Multi-interval

- Range limit 1

0…max. weight, transition from small to medium scale interval; only

when multiple range or multi-interval has been selected.

- Range limit 2

0…max. weight, transition from medium to large scale interval; only

when multiple range or multi-interval has been selected.