4.4.13

Parameter Input

Open the menu via

-[Weighingpoint]-[Calib]-[Param].

Weighingpoint/WP A/

Calibration

Measuretime

160 ms

Digital filter

bessel

External supply

8 - 12 VDC

Fcut

3.00 Hz This line is shown only if the filter is on.

Test mode

absolute

W

& M

none

Standstill time

0.50 s

Standstill range

1.00 d

[Measuretime]
Select the measuring time; possible values: 5, 10, 20, 40, 80, 160, 320, 640, 960, 1280, 1600 ms.
In 'legal-for-trade' mode select

≤1 s.

[Digital filter]

The digital filter can be switched on only with the measuring time set to

≤160 ms.

Select the filter characteristic [off], [bessel], [aperiod.], [butterw.], [tscheby.].

[Fcut]
Enter the cut-off frequency for the filter (0.1…80 Hz); the setting is dependent on the measuring time.

[External supply]
With external load cell supply (e.g. 7.5 V DC via 1626/60 with MX8 = closed), [below 8 VDC] can be selected to
adapt the sense voltage monitoring to the lower supply voltage.

[Test mode]
With [Absolute], the test value is calculated when the test is called. With [relative], the deviation from the
initially stored test value is displayed; see Chapter 4.4.11.

[W

& M]

Setting for 'legal-for-trade' mode; select [none], [OIML], [NTEP] (for USA) or [NSC] (for Australia),
see Chapter 4.4.13.1.

[Standstill time]
Settings [Standstill range] and [Standstill time] are required for determining the mechanical stability of the
scale. Input in seconds; permissible range 0.01 bis 2 sec. (max. measuring time x 32). If 0 is set, stability is not
checked. The stability time must not be less than the measuring time and not greater than 32 times the
measuring time.

[Standstill range]
The scale is stable as long as any changes in the weight value are within this range; permissible range:
0.01d to 10.00d. In 'legal-for-trade' mode select

≤1 d.