Commissioning, Pr 5220 instrument manual – Rice Lake PR5220 Ethernet Transmitter User Manual
Page 86
Advertising
Commissioning
PR 5220 Instrument Manual
EN-86
Sartorius
Weighingpoint/
WP A
Load Cell Information
Type
Pendeo process Load cell type
No of LC
4 Number of load cells
LC 1
101
Load cell serial number
LC 2
103
LC 3
104
LC 4
102
Press [View].
Search
View
Calib
Weighingpoint/WP A/
View
LC 1
101
1.958 t
LC 2
103
2.118 t
Load cell load
LC 3
104
1.610 t
LC 4
102
1.828 t
Press
to select the desired load cell.
Press [Info] to display the load cell data.
Info
Assign
Press
to return.
If necessary press [Assign] to assign the load
cells; see Chapter 4.6.7.