2 rs-485 interface, Rs-485 interface – Rice Lake PR5220 Ethernet Transmitter User Manual

Page 21

Advertising
background image

PR 5220 Instrument Manual

Installing the Instrument

Sartorius

EN-21

3.1.2

RS-485 Interface

The interface is intended for connecting a remote display, a PC for data transmission using the SMA protocol
or scale/terminal/digital load cells, type Pendeo for data transmission using the xBPI protocol.

Connection method

4-pin plug-in terminal block

Number of channels/type 1 RS-485, full/half duplex
Transfer rate (Bits/s)

300, 600, 1200, 2400, 4800, <9600>, 19200

Bits/stop bits

<8/1> or 7/1

Parity

<even>, <odd>, <none>

Signals

RxA (R-), RxB (R+), TxA, TxB

Electrical isolation

yes

Cable length

max. 1000 m

Cable type

Shielded twisted pair (e.g. LifYCY 2x2x0.20)

<...> = default settings (factory settings)