3 analog output, Analog output – Rice Lake PR5220 Ethernet Transmitter User Manual

Page 25

Advertising
background image

PR 5220 Instrument Manual

Installing the Instrument

Sartorius

EN-25

3.1.3

Analog Output

Connection method

4-pin plug-in terminal block

Number of outputs

1 current output,
output voltage via external resistor

Output

Gross, net weight or via ProfiBus

Range

0/4 ... 20mA, configurable

Resolution

e.g. 0 - 20 mA in max. 40,000 counts

Linearity error

@ 0 - 20mA: <0,05 %
@ 4 - 20 mA: <0,025 %

Temperature effect

<100 ppm/K

Load

0 ... max. 500 ¥

Protected against short

circuit

yes

Electrical isolation

yes

Cable length (shielded)

150 m (current output)

0/4…20mA

Analog signal,
current output


The current is supplied directly via
the terminals.

0…10V

Analog signal,
voltage output


The voltage level corresponds to the
voltage drop across the 500 ¥
(10 ppm/K) resistor.

Advertising