Commissioning, Pr 5220 instrument manual – Rice Lake PR5220 Ethernet Transmitter User Manual

Page 94

Advertising
background image

Commissioning

PR 5220 Instrument Manual

EN-94

Sartorius

Weighingpoint/WP A/

Calibration

Zerotrack range

0.25 d

Zerotrack step

0.25 d

Zerotrack time

1.0 s

Overload

9 d

Min

20 d

Range mode

Single range

[Zerotrack range]
Range within which the automatic zerotrack is balanced.
Setting range: 0.25…10000.00 d
For use in Legal-for-Trade mode a value of 0.25 d must be entered.

[Zerotrack step]
If a weight change exceeds the adjusted value, automatic tracking does not function any more.
Setting range for automatic tracking increments: 0.25... 10 d
For use in Legal-for-Trade mode a value of 0.25 d must be entered.

[Zerotrack time]
Time interval for automatic zero tracking.
Setting range: 0.0…25 s
At 0.0 s the tracking is switched off. For use in Legal-for-Trade mode a value of 1 s must be entered.

[Overload]
Weighing range above the maximum capacity (Max) without error message.
Setting range: 0…999900 d. For use in Legal-for-Trade mode a value of max. 9 d = e must be set.

[Min]
Minimum weight at which a print command can be triggered.
Setting range: 0…999900 d. For use in Legal-for-Trade mode a value of at least 20 d must be set.

[Range mode]
For scale range selection, see Chapter 4.4.13.2.

Advertising