Commissioning

PR 5220 Instrument Manual

EN-52

Sartorius

- Interface settings

- Communication type

SBI protocol, xBPI protocol

- Baudrate for SBI

150 baud, 300 baud, 600 baud, 1200 baud, 2400 baud, 4800 baud,

9600 baud, 19200 baud

- Parity for SBI

Mark, Space, Odd, Even

- Stopbits

1 stopbit, 2 stopbits

- Handshake

Software handshake, CTS with 2 chr.pau = CTS with 2 characters,

CTS with 1 chr.pau = CTS with 1 character

- Data output interval

with each display, after 2 updates, after 5 updates,after 10 update,

after 20 updates, after 50 updates, after 100 updates

- Parameter change

can be changed, cannot be changed

- Select specification group

- Specif. group 1 …6

Select specification group of the scale (see operating manual of the relevant

scale)

- Show device info

- Set user

User name of the connected device

- Set SBN

Address for xBPI at an interface must be <0 >, because there is no bus

operation.

- Config

- Type

xBPI-Scale

- W&M

<none>, OIML, NSC, NTEP

- Tare timeout

0.1 s ... <2.0 s> ... 25 s,

- Serial number

<0>, if >0, the serial number is checked (with verified scale)

- SBN Address

<0 > no bus operation.

- Param

- Assigned to

xBPI-Port 1

- Baudrate

Transmission rate: <9600>, 19200, 38400

- Bits

8

- Parity

odd

- Stopbits

<1>, 2