SMA Protocol

Sartorius

EN-131

Reply with Unknown Command

<LF> ? <CR>

A command from the controlling computer that is not implemented, or invalid, is replied
with an ASCII ‘?’.

Reply in Case of Communication Error

<LF> ! <CR>

A command from the controlling computer that is unknown to the scale due to a
communication error is replied with an ASCII ‘!’. This includes parity error or frame error
(if any).

Reply with Diagnosis Command
When a diagnosis command is given, the scale makes a test and gives a status reply.
<LF> <r> <e> <c> <m> <CR>
Reply format and meaning:

<LF>

Start of diagnosis reply

<r>

‘R’ = RAM or ROM error, ‘_’ = OK,

<e>

‘E’ = EEPR OM error, ‘_’ = OK

<c>

‘C’ = calibration error, ‘_’ = OK

<m>

Always: ‘_’ = OK

<CR>

Start of the diagnosis reply


Example: without error status

Command

Reply

<LF>D<CR>

<LF> <_> <_> <_> <_> <CR>