Er 4.4.13.1, Commissioning, Pr 5220 instrument manual – Rice Lake PR5220 Ethernet Transmitter User Manual

Page 68

Advertising
background image

Commissioning

PR 5220 Instrument Manual

EN-68

Sartorius

Weighingpoint/WP A/

Calibration

Tare timeout

2.5 s

Zeroset range

50.00 d

Zerotrack range

0.25 d

Zerotrack step

0.25 d

Zerotrack time

0.0 s

Overload

9 d

[Tare timeout]
Enter a timeout value between 0.1 and 25 s for a taring/zero set command that cannot be executed (e.g., if
scale mechanically unstable, filter settings faulty, resolution too high, stability condition too narrow).
[Zeroset range]
Determine a ±range around the zero point determined by the dead load during calibration; within this range:
-

the displayed gross weight can be set to zero by pressing the zero-setting key (or by a corresponding

external command), and

-

automatic zero tracking is active.

Available range: 0.00 d to 10000.00d

In 'legal-for-trade' mode a value

≤ 2 % of Max. must be entered. Example: 60 d for 3000e, class III.

[Zerotrack range]
Range within which automatic zero tracking compensates deviations; 0.25 to 10000.00d.
In 'legal-for-trade' mode a value of 0.25 d has to be entered.
[Zerotrack step]
Step for automatic tracking; 0.25 to 10d. In 'legal-for-trade' mode a value of 0.25 d has to be entered.

[Zerotrack time]
Enter a time interval for automatic zero tracking within 0.0 (tracking switched off) and 25 s.
In 'legal-for-trade' mode a value of 0.25 d has to be entered.

[Overload]
Weighing range above the maximum capacity (Max), without error message. Available range: 0 to 9999900 d.
In 'legal-for-trade' mode max. 9 d=e has to be entered.

Weighingpoint/WP A/

Calibration

Minimum weight

50 d

Range mode

Single range

[Minimum weight]
Minimum weight at which a print command can still be executed. Range is 0 to 9999900 d.
In 'legal-for-trade' mode min. 20 d has to be entered.

[Range mode]
For scale range selection, see Chapter 4.4.13.2.

Advertising