1 installation, 2 electrostatically sensitive components, 3 protective earth – Rice Lake PR5220 Ethernet Transmitter User Manual

Page 8: 4 supply voltage connection, Installation, Electrostatically sensitive components, Protective earth, Supply voltage connection, Safety information, Pr 5220 instrument manual

Advertising
background image

Safety Information

PR 5220 Instrument Manual

EN-8

Sartorius

1.4.1

Installation

The instrument is designed for mounting on standard rails (35 mm, acc. to DIN 46277).

Caution!
Excessive heat may reduce the instrument lifetime!
When mounting on the rail, make sure that the distance from other instruments left

and right of the module is at least 20 mm.

1.4.2

Electrostatically Sensitive Components

This instrument contains electrostatically sensitive components. For this reason, an equipotential bonding
conductor must be connected when working on the open instrument (antistatic protection).

1.4.3

Protective Earth

Connection to protective earth must be performed via the mounting rail.

1.4.4

Supply Voltage Connection

The supply voltage is 24V DC +10% / -15%.
Max. power consumption of
-

PR 5220/00: 6.5 W

-

PR 5220/01: 8.5 W

-

PR 5220/04: 8.5 W

-

PR 5220/06: 8.5 W

-

PR 5220/07: 8.5 W

For connection to 230/115 V AC, an external power supply
(e.g. Sartorius PR 1624/00 or Phoenix Mini Power) is required.