5 communication error, 7 fieldbus interface, 1 fieldbus interface protocol – Rice Lake PR5220 Ethernet Transmitter User Manual
Page 134: Communication error, Fieldbus interface, Fieldbus interface protocol, 7fieldbus interface, Pr 5220 instrument manual, Interface protocol
Fieldbus Interface
PR 5220 Instrument Manual
EN-134
Sartorius
6.5
Communication Error
When a communication error due to a parity error or a frame error (if used) was detected, the scale sends an
ASCII ‘!’ character. The only other error is the detection of an unknown or non-supported command. In this
case, an ASCII '?' character is sent as a reply. Dependent on the error messages, the controlling computer must
decide how to continue the scale operation.
7
Fieldbus Interface
7.1
Fieldbus Interface Protocol
The interface works with an 8-byte write window and an 8-byte read window. The fieldbus exchanges its data
cyclically with each slave. This means: In each cycle, 8 bytes are written and 8 bytes are read, also if the data
content is unchanged.
The fieldbus protocol ensures the data transport between the fieldbus master and the 2 x 8-byte data
windows.
The interface protocol runs under the fieldbus and manages the access to a multitude of different data.
Fieldbus Interface
Data and Functions with PR 5220
-
Weight data
-
Weight status
-
Limit values
-
Digital inputs
-
Digital outputs
-
Analog output
8-Byte
Write Window
8-Byte
Read Window
Interface
Protocol
Siemens