Basler Electric BE1-BPR User Manual

Page 139

Advertising
background image

9272000990 Rev J

BE1-BPR Installation

i

SECTION 7 • INSTALLATION

TABLE OF CONTENTS

SECTION 7 • INSTALLATION .................................................................................................................. 7-1

GENERAL .............................................................................................................................................. 7-1

OPERATING PRECAUTIONS ............................................................................................................... 7-1

Dielectric Test ..................................................................................................................................... 7-1

MOUNTING ............................................................................................................................................ 7-1

General ............................................................................................................................................... 7-1

Installing Escutcheon Plates .............................................................................................................. 7-6

CONNECTIONS..................................................................................................................................... 7-6

Terminations ....................................................................................................................................... 7-6

Typical Connections ........................................................................................................................... 7-6

CONTACT SENSING INPUTS .............................................................................................................. 7-9

COMMUNICATION CONNECTORS AND SETTINGS ....................................................................... 7-11

Front/Rear RS-232 Connectors........................................................................................................ 7-11

RS-485 Connections ........................................................................................................................ 7-13

Communication Settings .................................................................................................................. 7-13

Setup ................................................................................................................................................ 7-13

IRIG Input and Connections ............................................................................................................. 7-14

Figures
Figure 7-1. Overall Dimensions (Horizontal Rack Mount)

......................................................................... 7-2

Figure 7-2. Cutout Dimensions (Panel Mount)

.......................................................................................... 7-2

Figure 7-3. Overall Dimensions (Vertical Mount)

...................................................................................... 7-3

Figure 7-4. Overall Dimensions, Side View (Vertical Mount)

.................................................................... 7-4

Figure 7-5. Panel Drilling Diagram (Vertical Mount)

.................................................................................. 7-5

Figure 7-6. Terminals, Horizontal-Mount Unit

........................................................................................... 7-7

Figure 7-7. Terminals, Vertical-Mount Unit

................................................................................................ 7-8

Figure 7-8. Typical AC Sensing Connections

............................................................................................ 7-9

Figure 7-9. Typical DC Control Connections

............................................................................................. 7-9

Figure 7-10. Contact Sensing Jumpers Location

.................................................................................... 7-10

Figure 7-11. RS-232 Pin-Outs

................................................................................................................. 7-11

Figure 7-12. PC to BE1-BPR (Straight Cable)

........................................................................................ 7-12

Figure 7-13. Modem to BE1-BPR (Null Modem Cable)

........................................................................... 7-12

Figure 7-14. RFL 9660 Protective Relay Switch to BE1-BPR (Null Modem Cable)

................................ 7-12

Figure 7-15. SEL-2020 Communications Processor to BE1-BPR (Straight Cable)

................................ 7-13

Figure 7-16. RS-422/RS-485 DB-37 to BE1-BPR Cable Connection

..................................................... 7-14

Tables
Table 7-1. Contact Sensing Turn-On Voltage

......................................................................................... 7-10

Table 7-2. RS-232 Pinouts (Port0 and Port1A)

....................................................................................... 7-11

Table 7-3. RS-485 Pinouts (Port1B)

........................................................................................................ 7-13

Table 7-4. IRIG Pinouts

........................................................................................................................... 7-14


Advertising