Gr. P

Run time group P [r.Axx]
Program editing

This group is available when the instrument operates as
programmer only.

- Program selection - [r.A01]

Lower display: SE.xx if the selected program is a simple

program.

P.L.xx if the selected program is a linked

program.

Where xx is the number of segments of the

simple program or the number of simple
programs used for the linked program.

Ranges: - from 1 to 90 for simple program; after 90

- from L1 to L9 for linked program

NOTES:
1) When the selected program is a new program, the PRG

indicator will flash and xx will be equal to 0.

2) If no segment is available, the instrument will show the

existing programs only.

3) It is not possible to select a linked program (from L1 to L9) if

no simple program is programmed.

- Soak time engineering units selection
- [r.A02]

This parameter can be modified only when the selected program
is not running and it is not a linked program.
Upper display: Pr. xx

where xx is the number of the selected
program

Range: "hh.ññ" for hours and minutes

"ññ.ss" for minutes and seconds.

- Ramp time engineering units selection
- [r.A03]

This parameter can be modified only when the selected program
is not running and it is not a linked program.
Upper display: Pr. xx

where xx is the number of the selected
program

Range: "hh.ññ" for hours and minutes

"ññ.ss" for minutes and seconds.
"GrAd" for gradient in digit/hour.