Super Systems 20PQ User Manual

Page 158

Advertising
background image

A. 4

Pb 5

= 4.0 %

HYS 5

= 0.5 %

ti 5

= 4.00 mm.ss

td 5

= 1.00 mm.ss

IP 5

= 50.0 (If only one control output is configured).

0.0 (If two control outputs, without split range,
are configured).

r.Gn 5

= 1.00

OLP.5

= 0

Run time group 5 [r.Exx]

PARAMETER

DEFAULT VALUE

ArW

= 100%

Sñ.tt

= 1.00 m

Sñ.db

= 5%

ñ.OLL

= 0.0%

ñ.OLH

= 100.0%

ñ.rñP

= Inf

ñC.CY

= 15 s (If relay output)

2 s (If SSR output)

S.OLL

= 0.0%

S.OLH

= 100.0%

S.rñP

= Inf

SC.CY

= 15 s (If relay output)

2 s (If SSR output)

rL

= Initial range value

rH

= Final range value

Grd1

= Inf

Grd2

= Inf

tOL

= Inf

E.Añ

= On

E.Lr

= On

E.rd

= On

Run time group 6 [r.Fxx]

PARAMETER

DEFAULT VALUE

A1.tP

= Proc

A1.Cn

= H.A.

A1.Ac

= rEV

A1.St

= OFF

A2.tP

= Proc

A2.Cn

= H.A.

A2.Ac

= rEV

A2.St

= OFF

A3.tP

= Proc

A3.Cn

= H.A.

XkP-A-C2.P65

10/30/01, 9:44 AM

4

Advertising