Super Systems 20PQ User Manual

Page 32

Advertising
background image

28

By

s or t push-button it is possible to select between:

=

(monitor) this selection allows you to monitor but
not to modify the value assigned to the configura-
tion parameters

=

(modify) this selection allows you to monitor and
to modify the value assigned to the configuration
parameters.

NOTES:
1) During monitor mode, the instrument continues to operate as

in run time mode.

2) When modify mode is started, the instrument stops the

control and:
- sets to OFF the control outputs;
- turns to OFF the bargraph displays (25Q only);
- sets analog retransmissions to the retransmitted initial

scale value;

- sets alarms in no alarm condition;
- sets to OFF the events;
- disables the serial link;
- the time out will be removed.

3) When the modify mode is disabled by V101 (V101.3), the

s

or

t push-button pressure has no effect.

MONITOR MODE
During the run time mode, it is possible to monitor but not modify
all configuration parameters.
When it is desired to verify the instrument configuration, proceed
as follows:
1) Push the MENU push-button for more than 5 seconds: the

display will show:

.

2) Push the MENU push-button the display will show:

it shows that configuration group 1 is selected and it
encompasses all the input parameters.

The configuration parameter "Monitor mode" follows the "Modify
mode" sequence.
NOTES:
1) During monitor mode, the instrument continues to operate as

in run time mode.

XKP-1-C2.p65

10/30/01, 9:37 AM

28

Advertising