Series 9205 Operations Manual Rev A

115

Set Menu Security

The Set Menu Security menu option is a feature that is used to limit access to certain menu options and

parameters that are vital to successful operation and communication of your instrument. This page comes

pre-configured by Super Systems Inc. and should not be adjusted without consulting SSi. The options are

operator, supervisor, or administrator.

Curve Entry

Most types of inputs that are used in SSi controllers

are already setup with a curve built for most every

type of thermocouple available, certain vacuum

sensors, etc. However, if an application calls for an

input without a standard curve, the curve can be

built using this option. Voltages can be paired with

corresponding values to create a sensor curve

based off of a provided equation or data. This allows

the controller to make appropriate readings from

the sensor.

The first screen shows that five separate curves can

be edited. Selecting one of Curve 1-5 and pressing

Edit will display the screen where new curves can

be assigned. The type can be toggled between

Linear and None.

Thirty-two points can be assigned by selecting one

of the points and pressing Edit. This allows the

operator to change the Millivolts and the

corresponding Value by clicking on each option.

Note that all 32 points do not need to be entered;

however, the more points that are entered, the more precise the calculated value will be. Any values that

are not entered should be set to values beyond (above or below) the ranges entered.

Curve Type

This is the type of curve. The options are none or linear.

Control Range

This is the control range for the curve. The range is 0 to 32000.

mV

X

(1 – 32)

Clicking on this value will display an input box from which the user can select a new millivolt value. The

range is from 0 to 32000.

Vac

X

(1 – 32)

Clicking on this value will display an input box from which the user can select a new vacuum value. The

range is from 0 to 32000.