Programmer description, Wait, Rogrammer – Super Systems 9205 Series User Manual

Page 132: Escription

Advertising
background image

Series 9205 Operations Manual Rev A

131

Programmer Description

The Series 9205 Recipe Programmer provides a convenient operator interface and recipe

programmer.

The programmer uses enhanced opcodes that reduce the number of steps required for a program.

Each step may consist of: an opcode, a temperature value column, an atmosphere value column,

and an option value column. The opcode determines how and if each of the three values is used.

An explanation of wait, wait up, and wait down options can be found at the end of this chapter.

Each opcode will be listed in the following format for readability:

Opcode

Temperature Value Column

Atmosphere Value Column

Option Value Column

Description

Wait

When using the option wait with a set point Opcode, the recipe will not advance to the next step until the PV

value falls within the wait limit band. The upper limit of this band is value of the PV set point plus the wait

limit. The lower limit of this band is the value of the PV set point minus the wait limi. The wait limit band is

the range between the upper limit and the lower limit. The recipe will then continue to the next step.