Furnace setup, Urnace, Etup – Super Systems 9205 Series User Manual

Page 98

Advertising
background image

Series 9205 Operations Manual Rev A

97

Temp Zone Number

This option will allow the user to set the zone number for the assignment. The range is 0 – 5.

Temp Zone Offset

This option will allow the user to enter an offset for the assignment. The range is -4000 – 4000.

Furnace Setup

The Furnace Setup menu option is an administrative

access only option. Do not make any adjustments on

the screen without first contacting Super Systems, Inc.

at (513) 772-0060.

Note for controllers with Cascade

control: When in cascade mode, the 9xxx treats loop 2

as the furnace loop and loop 3 as the load loop. It feeds

the output of the load loop into the set point of the

furnace loop

.

PVT Type

There are nine PVT choices for the 9205:

%Carbon

Cascade

Dew Point

% Carbon + Redundant TC

Millivolts

Dew Point + Redundant TC

Multi-loop

Millivolts + Redundant TC

% Carbon + Dual Temp

%Carbon: Process variable will calculate for carbon

potential along with a temperature loop. Loop 1 is

based off of Input 1 (terminals 31, 32 probe sensor

millivolts) and Input 2 (terminals 29, 30 probe TC).

These two inputs together constitute loop 1. Loop 2

comes from Input 3 (terminals 27, 28) which is

temperature control.

Cascade: Three loops of temperature control work together in a cascade setting.

Dew Point: Control will be for dew point along with a temperature loop. Loop 1 is based off of Input 1

(terminals 31, 32 probe sensor millivolts) and Input 2 (terminals 29, 30 probe TC). These two inputs

together constitute loop 1. Loop 2 comes from Input 3 (terminals 27, 28) which is temperature control.

%Carbon + Redundant TC: This functions the same way as the %Carbon option with an additional

thermocouple for Loop 3. The two thermocouples are used to control carbon, and the operator can choose

the setting that will be used.

Millivolts: Control is based on what the millivolt reading is and also reads temperature.

Dew Point + Redundant TC: This functions the same way as the Dew Point option with an additional

thermocouple for Loop 3. The two thermocouples are used to control dew point, and the operator can

choose the setting that will be used.

Multiloop: Three loops of control can be assigned as selected.