The Event ON/OFF Bitmap field will set the final condition of the events in the event mask. The opcode will

ignore the bits not in the mask and either set or reset the bits depending upon their states in the bitmap.

The options are: 0 – 15.

MEVT_OUT_1

Temperature Setpoint

Event Mask

Event ON/OFF Bitmap

This opcode will set multiple output events 16 through 31.

The Temperature Setpoint is an optional setpoint to send down. The range is -301 (disable) – 30000.

The Event Mask is the events to enable, which is the events affected. The options are: 0 – 15.

Note – Even

though the events listed are 0 – 15, they correspond to 16 – 31

.

The Event ON/OFF Bitmap field will set the final condition of the events in the event mask. The opcode will

ignore the bits not in the mask and either set or reset the bits depending upon their states in the bitmap.

The options are: 0 – 15.

Note – Even though the events listed are 0 – 15, they correspond to 16 – 31

.

MEVT_OUT_2

Temperature Setpoint

Event Mask

Event ON/OFF Bitmap

This opcode will set multiple output events 32 through 47.

The Temperature Setpoint is an optional setpoint to send down. The range is -301 (disable) – 30000.

The Event Mask is the events to enable, which is the events affected. The options are: 0 – 15.

Note – Even

though the events listed are 0 – 15, they correspond to 32 – 47

.

The Event ON/OFF Bitmap field will set the final condition of the events in the event mask. The opcode will

ignore the bits not in the mask and either set or reset the bits depending upon their states in the bitmap.

The options are: 0 – 15.

Note – Even though the events listed are 0 – 15, they correspond to 32 – 47

.

MV_INQ

N/A

Millivolt Level

Option

The millivolt inquiry is used to wait for the probe millivolts to reach the value specified in the atmosphere

data. The range is -1 to 9999.

The

LIMIT

opcode immediately following this opcode sets a time limit on the wait.

A

BRANCH

opcode immediately following this opcode can be used to change the program flow based on the

inquiry results.

NO-OP

N/A

N/A

N/A

This is a no operation code, and it does nothing. It is used as a place holder on programs that are less than

24 steps.

PIDLOAD

Loop 2

Loop 1

Loop 3

This opcode will load an alternate PID set from the controller memory.

The Loop 1 field is the alternate PID loop to use for loop 1. A value of 0 will disable the loop PID. The range

is 0 – 16.

The Loop 2 field is the alternate PID loop to use for loop 2. A value of 0 will disable the loop PID. The range

is 0 – 16.

The Loop 3 field is the alternate PID loop to use for loop 3. A value of 0 will disable the loop PID. The range

is 0 – 16.

The alternate PID loops can be set up on the

Alternate PID Setup

screen. See the

Alternate PID Setup

section for more information.