Probe burnoff setup, Robe, Urnoff – Super Systems 9205 Series User Manual

Page 84: Etup

Advertising
background image

Series 9205 Operations Manual Rev A

83

Probe Burnoff Setup

Configurator – Probe Burnoff Setup menu option

When a probe is in a furnace, soot will collect in the end of the probe, which will have a negative effect on

the performance of the probe. Burnoffs are used to clean out the built-up carbon by burning it off of the

probe.

This menu option allows the user to modify the settings that are associated with the probe burnoff (menu

option

Burnoff

).

Burnoff Time:

This is the duration of the burnoff measured in seconds. SSi recommends a 90 second burnoff, and this will

be the default value. However, it can be adjusted by the operator. Clicking on the value will allow the user

to change the value.

Configurator – Enter new burnoff value