Super Systems 9205 Series User Manual

Page 143

Advertising
background image

Series 9205 Operations Manual Rev A

142

Controller

Source

Location

Write

Register

Read

Scale

Write Scale

Description

Eurotherm 2404

1

1

1

1

%C Actual

(Modbus Mode)

5

5

1

1

%C Setpoint

72

11073

1

1

Probe Temperature

61

11062

1

1

Probe Millivolts

4

4

1

1

%C Percent Output

0

0

1

1

CO Factor or Equivalent

0

0

1

1

H Factor or Equivalent


Controller

Source

Location

Write

Register

Read

Scale

Write Scale

Description

Eurotherm 2500

1

1

1

1

%C Actual

(Modbus Mode)

5

5

1

1

%C Setpoint

72

11073

1

1

Probe Temperature

Assumes Loop 1 =

61

11062

1

1

Probe Millivolts

Atmosphere

4

4

1

1

%C Percent Output

68

11069

1

1

CO Factor or Equivalent

68

11069

1

1

H Factor or Equivalent


Controller

Source

Location

Write

Register

Read

Scale

Write Scale

Description

Carbpro 3.5

6

28

1

1

%C Actual

(MMI Mode)

1

1

1

1

%C Setpoint

5

25

8

8

Probe Temperature

4

24

8

8

Probe Millivolts

11

117

1

1

%C Percent Output

13

7

1

1

CO Factor or Equivalent

14

8

1

1

H Factor or Equivalent


Controller

Source

Location

Write

Register

Read

Scale

Write Scale

Description

Carbpro 3.0

6

28

4

4

%C Actual

(MMI Mode)

1

1

1

1

%C Setpoint

5

25

8

8

Probe Temperature

4

24

2

2

Probe Millivolts

11

117

1

1

%C Percent Output

13

7

1

1

CO Factor or Equivalent

14

8

1

1

H Factor or Equivalent


Controller

Source

Location

Write

Register

Read

Scale

Write Scale

Description

Carbpc

20

20

1

1

%C Actual

(MMI Mode)

6

6

1

1

%C Setpoint

17

17

8

8

Probe Temperature

18

18

8

8

Probe Millivolts

64

64

41

41

%C Percent Output

3

3

1

1

CO Factor or Equivalent

4

4

1

1

H Factor or Equivalent