[:SOURce]:SWEep:LIST:INITialize:FSTep

Syntax

[:SOURce]:SWEep:LIST:INITialize:FSTep

Description

Recalculate the data point set in the current step sweep to generate a new sweep list.

Explanation

 In the new sweep list, "ListNum" depends on the "Points" of the step sweep.

 "Frequency" depends on the "Start Frequency" and "Stop Frequency" of the step

sweep.

 "Amplitude" depends on the "start Level" and "Stop Level" of the step sweep.

 "Time" depends on the "Dwell Time" of the step sweep.

Related

Commands

[:SOURce]:SWEep:STEP:DWELl
[:SOURce]:SWEep:STEP:POINts
[:SOURce]:SWEep:STEP:STARt:FREQuency
[:SOURce]:SWEep:STEP:STARt:LEVel
[:SOURce]:SWEep:STEP:STOP:FREQuency
[:SOURce]:SWEep:STEP:STOP:LEVel

[:SOURce]:SWEep:LIST:INITialize:PRESet

Syntax

[:SOURce]:SWEep:LIST:INITialize:PRESet

Description

Reset the sweep list to factory setting.

Explanation

 After resetting the sweep list using this command, the sweep list only contains

one frequency point (6GHz) and level point (-140dBm).

 You can use the

[:SOURce]:SWEep:LIST:ADDList

and

[:SOURce]:SWEep:LIST:DELete

commands to re-edit the current sweep list.