[:SOURce]:SWEep:POINt:TRIGger:TYPE

Syntax

[:SOURce]:SWEep:POINt:TRIGger:TYPE AUTO|KEY|BUS|EXT
[:SOURce]:SWEep:POINt:TRIGger:TYPE?

Description

Set the point trigger type of the sweep.
Query the point trigger type of the sweep.

Parameter

Name

Type

Range

Default

AUTO|KEY|BUS|EXT Discrete

AUTO|KEY|BUS|EXT

AUTO

Explanation

 AUTO: select "Auto" trigger mode. If the sweep mode is set to "cont", the

instrument sweeps each sweep point continuously within a sweep period

when a sweep type is selected. If the sweep mode is set to "Single", the

instrument performs a sweep and then stops after the

[:SOURce]:SWEep:EXECute

command is sent and when the single sweep

condition is met.

 KEY: select "Key" trigger mode. If the sweep mode is set to "Cont", the

instrument starts to sweep a sweep point each time Trigger at the front
panel is pressed. If the sweep mode is set to "Single", the instrument sweeps
a point each time Trigger at the front panel is pressed and stops after a
sweep period after the

[:SOURce]:SWEep:EXECute

command is sent and

when the single sweep condition is met.

 BUS: select "Bus" trigger mode. If the sweep mode is set to "Cont", the

instrument starts to sweep a point each time the

*TRG

or

:TRIGger[:SWEep][:IMMediate]

command is sent. If the sweep mode is set

to "Single", the instrument sweeps a point each time the

*TRG

or

:TRIGger[:SWEep][:IMMediate]

command is sent and stops after a sweep

period after the

[:SOURce]:SWEep:EXECute

command is sent and when the

single sweep condition is met.

 EXT: select "Ext" trigger mode. The RF signal generator receives the trigger

signal input from the [TRIGGER IN] connector at the rear panel. If the

sweep mode is set to "Cont", the instrument starts to sweep a point each time

a TTL pulse signal with the specified polarity is received. If the sweep mode is

set to "Single", the instrument sweeps a point each time a TTL pulse signal

with the specified polarity is received and stops after a sweep period after the

[:SOURce]:SWEep:EXECute

command is sent and when the single sweep

condition is met.

Note: The above explanations are only valid when the trigger mode of the

corresponding sweep period is met.

 When executing the sweep operation, the priority of the required conditions

is: single sweep  trigger mode  point trigger mode.

Return Format

The query returns the point trigger type, for example, AUTO.

Example

:SWE:POIN:TRIG:TYPE AUTO
:SWE:POIN:TRIG:TYPE?

Related

Commands

[:SOURce]:SWEep:EXECute
[:SOURce]:SWEep:MODE
[:SOURce]:SWEep:SWEep:TRIGger:TYPE
*TRG
:TRIGger[:SWEep][:IMMediate]