RIGOL DSG3000 Series User Manual

Page 121

Advertising
background image

Chapter 2 Command System

RIGOL

DSG3000 Programming Guide

2-101

The definitions of the questionable status register are as shown in the table below. Wherein, bit 0 to bit 2,

bit 6 and bit 11 to bit 15 are not used and will be always treated as 0.

Bit

Value

Definition

0

0

Not Used

1

0

Not Used

2

0

Not Used

3

8

Power

4

16

Temperature

5

32

Frequency

6

0

Not Used

7

128

Modulation

8

256

Calibration

9

512

Selftest

10

1024

Connect

11

0

Not Used

12

0

Not Used

13

0

Not Used

14

0

Not Used

15

0

Not Used

The definitions of the operation status register are as shown in the table below. Wherein, bit 0, bit 2, bit 4,

bit 6, bit 7 and bit 9 to bit 15 are not used and will always be treated as 0.

Bit

Value

Definition

0

0

Not Used

1

2

Setting

2

0

Not Used

3

8

Sweeping

4

0

Not Used

5

32

Waiting for Trigger

6

0

Not Used

7

0

Not Used

8

256

Sweep Calculation

9

0

Not Used

10

0

Not Used

11

0

Not Used

12

0

Not Used

13

0

Not Used

14

0

Not Used

15

0

Not Used