Chapter 2 Command System

RIGOL

DSG3000 Programming Guide

2-127

:SYSTem:LANGuage

Syntax

:SYSTem:LANGuage CHINese|ENGLish
:SYSTem:LANGuage?

Description

Set the system language.
Query the system language.

Parameter

Name

Type

Range

Default

CHINese|ENGLish

Discrete

CHINese|ENGLish

NULL

Return Format

The query returns CHINESE or ENGLISH.

Example

:SYST:LANG CHIN
:SYST:LANG?

:SYSTem:LKEY

Syntax

:SYSTem:LKEY <license key>

Description

Install and activate the option of the instrument.

Parameter

Name

Type

Range

Default

<license key>

String

Serial number of the option you

bought

NULL

Explanation

The serial number for each option is unique and can only be used by one

instrument (the serial number of the option corresponds to the serial number of

the instrument you bought).

Example

:SYST:LKEY QA7ZCZEH6AC54SFNKA853MS5CB3A

:SYSTem:POWer:ON:TYPE

Syntax

:SYSTem:POWer:ON:TYPE LAST|PRESet
:SYSTem:POWer:ON:TYPE?

Description

Select the instrument configuration to be used at start-up.
Query the instrument configuration to be used at start-up.

Parameter

Name

Type

Range

Default

LAST|PRESet

Discrete

LAST|PRESet

NULL

Explanation

 LAST: the instrument loads the system configuration used before the last

power-off automatically at start-up.

 PRESet: the instrument loads the settings defined by

the

:SYSTem:PRESet:TYPE

command automatically at start-up.

Return Format

The query returns LAST or PRESET.

Example

:SYST:POW:ON:TYPE LAST
:SYST:POW:ON:TYPE?

Related

Command

:SYSTem:PRESet:TYPE