[:SOURce]:IQ:TRIGger:DURation

Syntax

[:SOURce]:IQ:TRIGger:DURation <value>
[:SOURce]:IQ:TRIGger:DURation?

Description

Set the duration of the single trigger signal.
Query the duration of the single trigger signal.

Parameter

Name

Type

Range

Default

<value>

Integer

1 to 65535

1

Explanation

 This command is valid only when selecting "Single" operation mode. <value>

describes the number of points (

r

N

). The actual time (

r

T

) can be obtained

according to the current sample rate (

a

S

):

a

r

r

S

N

T

=

.

 After the duration is set, you can use the up/down direction keys or knob to

modify the duration at the current step. You can query or set the current step

using the

[:SOURce]:IQ:TRIGger:DURation:STEP

command.

Return Format

The query returns the duration of the single output signal, for example, 4000.

Example

:IQ:TRIG:DUR 4000
:IQ:TRIG:DUR?

Related

Commands

[:SOURce]:IQ:TRIGger:DURation:STEP
[:SOURce]:IQ:TRIGger:OPTMode

[:SOURce]:IQ:TRIGger:DURation:STEP

Syntax

[:SOURce]:IQ:TRIGger:DURation:STEP <value>
[:SOURce]:IQ:TRIGger:DURation:STEP?

Description

Set the duration step.
Query the duration step.

Parameter

Name

Type

Range

Default

<value>

Integer

1 to 10000

1

Explanation

After setting the duration step, you can use the up/down direction keys or knob to

modify the duration at the current step. At this point, you can query or reset the

duration using the

[:SOURce]:IQ:TRIGger:DURation

command.

Return Format

The query returns the duration step, for example, 500.

Example

:IQ:TRIG:DUR:STEP 500
:IQ:TRIG:DUR:STEP?

Related

Command

[:SOURce]:IQ:TRIGger:DURation