Source]:lfoutput:sweptsine:xpolar, Source]:modulation:state, Source]:phase command subsystem – RIGOL DSG3000 Series User Manual

Page 78: Source]:modulation:state -58, Source]:phase command subsystem -58

Advertising
background image

RIGOL

Chapter 2

Command System

2-58

DSG3000 Programming Guide

[:SOURce]:LFOutput:SWEPtsine:XPOLar

Syntax

[:SOURce]:LFOutput:SWEPtsine:XPOLar NEG|POS
[:SOURce]:LFOutput:SWEPtsine:XPOLar?

Description

Set the external trigger polarity of sweep-sine.
Query the external trigger polarity of sweep-sine.

Parameter

Name

Type

Range

Default

NEG|POS

Discrete

NEG|POS

POS

Explanation

 The parameter NEG|POS can set the polarity of the external trigger signal of

sweep-sine to "Neg" or "Pos".

 This command is only valid when the trigger mode of sweep-sine is currently

set to "Ext".

Return Format

The query returns NEG or POS.

Example

:LFO:SWEP:XPOL NEG
:LFO:SWEP:XPOL?

Related

Command

[:SOURce]:LFOutput:SWEPtsine:TRIGger

[:SOURce]:MODulation:STATe

Syntax

[:SOURce]:MODulation:STATe ON|OFF|1|0
[:SOURce]:MODulation:STATe?

Description

Turn on or off all the modulation outputs.
Query the on/off state of all the modulation outputs.

Parameter

Name

Type

Range

Default

ON|OFF|1|0

Bool

ON|OFF|1|0

OFF

Explanation

 ON: turn on all the modulation outputs. The backlight of the MOD output

control key turns on.

 OFF: turn off all the modulation outputs. The backlight of the MOD output

control key turns off.

Return Format

The query returns 1 or 0.

Example

:MOD:STAT ON /*Turn on all the modulation outputs*/
:MOD:STAT? /*The query returns 1*/

[:SOURce]:PHASe Command Subsystem


Command List:

[:SOURce]:PHASe

[:SOURce]:PHASe:RESet

[:SOURce]:PHASe:STEP[:INCRement]