[:SOURce]:PULM:SOURce

Syntax

[:SOURce]:PULM:SOURce INTernal|EXTernal
[:SOURce]:PULM:SOURce?

Description

Set the pulse modulation source.
Query the pulse modulation source.

Parameter

Name

Type

Range

Default

INTernal|EXTernal

Discrete

INTernal|EXTernal

INTernal

Explanation

 INTernal: select "Int" modulation source. At this point, the modulating signal is

provided by the internal pulse generator. When the "Pulse Out" is turned on,

the pulse signal generated by the internal pulse generator can be output via the

[PULSE IN/OUT] connector at the rear panel.

 EXTernal: select "Ext" modulation source. At this point, the RF signal genenraot

recieves the external pulse modulating signal input from the [PULSE IN/OUT]

connector at the rear panel.

Return Format

The query returns the pulse modulation source (INT or EXT).

Example

:PULM:SOUR EXT
:PULM:SOUR?

Related

Command

[:SOURce]:PULM:OUT:STATe

[:SOURce]:PULM:STATe

Syntax

[:SOURce]:PULM:STATe ON|OFF|1|0
[:SOURce]:PULM:STATe?

Description

Set the state of the pulse modulation.
Query the state of the pulse modulation.

Parameter

Name

Type

Range

Default

ON|OFF|1|0

Bool

ON|OFF|1|0

OFF

Explanation

 ON: turn on the pulse modulation switch to enable the pulse modulation

function.

 OFF: turn off the pulse modulation switch to disable the pulse modulation

function.

Return Format

The query returns 1 or 0.

Example

:PULM:STAT ON /*Turn on the pulse modulation switch*/
:PULM:STAT? /*Query the state of the pulse modulation and the query

returns 1*/