Source]:pulm:delay – RIGOL DSG3000 Series User Manual

Page 86

Advertising
background image

RIGOL

Chapter 2

Command System

2-66

DSG3000 Programming Guide

[:SOURce]:PULM:DELay

Syntax

[:SOURce]:PULM:DELay <value>

[:SOURce]:PULM:DELay?

Description

Set the delay between the start of #1 pulse and the start of #2 pulse of the double

pulse modulating signal.
Query the delay between the start of #1 pulse and the start of #2 pulse of the

double pulse modulating signal.

Parameter

Name

Type

Range

Default

<value>

Real

20ns to 170s-20ns

600us

Explanation

 You can use this command to set the pulse delay when the modulation source

is set to "Int" and the pulse mode is set to "Double". Otherwise, this

command is invalid.

 When <value> is set in "Number" form, the default unit is s. Besides,

<value> can also be set in "Number + Unit" form, for example, 2000ms.

 The default unit of the return value is s.

 After setting the pulse delay, you can use the up/down direction keys or knob

to modify the delay at the current step. At this point, you can query or set the

current step using the

[:SOURce]:PULM:DELay:STEP

command.

Return Format

The query returns the pulse delay of the double pulse modulating signal, for

example, 2.

Example

:PULM:DEL 2000ms
:PULM:DEL?

Related

Commands

[:SOURce]:PULM:DELay:STEP
[:SOURce]:PULM:MODE
[:SOURce]:PULM:SOURce