Source]:phase, Source]:phase:reset – RIGOL DSG3000 Series User Manual

Page 79

Advertising
background image

Chapter 2 Command System

RIGOL

DSG3000 Programming Guide

2-59

[:SOURce]:PHASe

Syntax

[:SOURce]:PHASe <value>
[:SOURce]:PHASe?

Description

Set the phase offset of RF output.
Query the phase offset of RF output.

Parameter

Name

Type

Range

Default

<value>

Real

-720deg to 720deg

0deg

Explanation

 When <value> is set in "Number" form, the default unit is deg. Besides,

<value> can also be set in "Number + Unit" form, for example, 35deg.

 The default unit of the return value is deg.

 After setting the RF phase offset, you can use the up/down direction keys or

knob to modify the phase offset at the current step. At this point, you can

query or set the current step using the

[:SOURce]:PHASe:STEP[:INCRement]

command.

Return Format

The query returns the phase offset of RF output, for example, 35.000000.

Example

:PHAS 35
:PHAS?

Related

Command

[:SOURce]:PHASe:STEP[:INCRement]

[:SOURce]:PHASe:RESet

Syntax

[:SOURce]:PHASe:RESet

Description

Reset the current phase offset to 0deg.

Related

Command

[:SOURce]:PHASe

Advertising