POD can access other CPUs on the NET II(/B) or NET/10 when POD is connected to one of the link units

that the data link system or network system consists of.

Select “A Link + Net10” as PLC setting when configuring the screen data on the panel editor.

To access other CPU on the NET II (/B) or NET/10 from POD.

• In case of NET II(/B), only the network which has the CPU with the link unit connected to the POD (e.g.

No. 1) can be accessed.

(Available CPU No.: 0 to 30)

• In case of NET/10, other networks (No. 2, No. 3) can be accessed in addition to the network No. 1.

(Available CPU No.: 1 to 30)

To read/write the memories of the CPU(e.g. 1-1 of CPU) which has the link unit to be connected to the

POD :

Set the CPU No. to “31” on the

panel editor.

Response time will be equivalent to

the case of 1 : 1 communication.

Please note that response will be delayed

due to the transient transmission when

the CPU No. is set to other than “31”.

In this case, use [OUT_ENQ] command of the [SYS] to

program the macro. A CPU from a different network

cannot be accessed on the same screen.

When accessing PLCs of other network numbers on

NET/10, specify the network number to be connected

with the screens Open Macro in Panel Editor.

CPU
(1-1)

Link Unit

CPU
(1-5)

CPU
(1-4)

CPU
(1-3)

CPU
(1-2)
(2-2)

CPU
(2-5)

CPU
(2-1)

CPU
(2-4)

CPU
(3-5)

CPU
(3-4)

CPU
(3-3)

CPU
(3-2)

CPU
(2-3)
(3-1)

Network No. 1

Network No. 2

Network No. 3

POD