27 allen-bradley plc . 2, Allen-bradley plc • 2 -80, Allen-bradley plc • 2 – Fujitronic Programmable Operation Display UG520H-x User Manual

Page 149: Available plc, Communication setting

Advertising
background image

2 - 80

27

Available PLC

*

When using RS232C program transfer cable made by Allen-Bradley , connect the cable of

[Wiring Diagram 3] to the D-sub 9 pin side of program transfer cable to communicate with POD .

Communication Setting

The recommended communication parameter setting of both PLC and POD is as follows:

SLC500 series

Micro Logix 1000

PLC

SLC 5/03 or later models

RS-232C [Wiring Diagram 2]
RS-422 [Wiring Diagram 4]

1747-KE

CPU (Processor module)
RS-232C channel

RS-232C [Wiring Diagram 1]

Select PLC Type

SLC500

Micro Logix 1000 Micro Logix 1000

Port on a CPU

RS-232C program transfer
cable made by Allen-Bradley

+ RS-232C [Wiring Diagram 3]

*

Link Unit

Wiring Diagram

Port

Transmission
Control Mode

RS-232C

RS-422

not supported on Channel 0

0

19200bps

Even

8

Baud Rate

Parity

Transmission

Code

Data Length

Stop Bit

1

Protocol

Error Check

Response

Item

Setting of PLC

0

19200bps

Even

8

1

Comm. Parameter of POD

Full duplex (fixed)

BCC (fixed)

NO (fixed)

Allen-Bradley PLC • 2

(SLC500 series •Micro Logix1000)

Port

0

9600bps

Baud Rate

Parity

Transmission

Code

Data Length

Stop Bit

Error Check

Item

Setting of PLC

0

9600bps

None

8

1

None (fixed)

8 (fixed)

1 (fixed)

CRC (fixed)

Comm. Parameter of POD

27 Allen-Bradley PLC

2

Advertising