2 - 143

TOYO DENKI PLC

(uGPC sx series)

Available PLC

*

Only one unit of POD can be connected to one link unit, except for “Multi-link 2” connection.

Communication Setting

The recommended communication parameter setting of both PLC and POD is as follows:

*

No function block (FB) settings are required on the PLC.

Available Memory

Set the memory to the extent of the memory range of each PLC model.

Use TYPE number to assign indirect memory for macro programs.

To set an indirect memory using a macro, specify the CPU No. using the extended code.

Indirect memory setting by macro is not available for input (I) or output (Q) memory.

Standard Memory

TYPE

Remarks

I

(input memory)

-

O

(output memory)

-

M

(standard memory)

2

RM (retain memory)

4

SM

(system memory)

8

PLC

NP1L-RS2

NP1L-RS4

NP1L-RS1

RS-232C [Wiring Diagram 1]

RS-485 [Wiring Diagram 2]

RS-232C [Wiring Diagram 1]

RS-485 [Wiring Diagram 2]

Select PLC Type

uGPCsx

Series

UG00C-S

uGPCsx CPU

uGPCsx Series

Wiring Diagram

Link Unit

Transmission
Control Mode

RS-232C

RS-422

Baud Rate

Parity

Data Length

Stop Bit

Item

Setting of PLC

RS-232C

RS-422

Mode 2

Mode 1

Comm. Parameter of POD

1 (fixed)

8 (fixed)

Even (fixed)

38400bps (fixed)

57

57 TOYO DENKI PLC