Switch setting of link unit – Fujitronic Programmable Operation Display UG520H-x User Manual

Page 113

Advertising
background image

2 - 44

Switch Setting of Link Unit

Baud rate: 19200bps

PLC System Memory Setting (in case of a communication port)

Baud rate: 19200bps

Available Memory

*

1 To set up Fn (file register), input [File No.] + [: (colon)] + [address]

Set the memory to the extent of the memory range of each PLC model.

Use TYPE number to assign indirect memory for macro programs.

SW0

Swtich

SW1

SW2

SW3-1

SW3-2

SW3-3

SW3-4

SW4

SW7

4

1

0

OFF

ON

OFF

ON

0

ON

Setting

Contents

Command mode

Station address (lower half)

Station address (upper half)

Not used

4-wire system

Not used

Even parity

Baud rate
0: 19200 1: 9600 2: 4800 3: 2400
4: 1200 5: 600

Teminating resistance provided

0

#0236

#0237

0

1

1

0

0

0

0

1

0

0

0

0

0

0

0

D7

D6

D5

D4

D3

D2

D1

D0

System memory

15 Sharp PLC

1

<E.g.> F1 : 00002

File No.

Address

Colon

Memory

TYPE

Remarks

X9XXX (register)

0

XXXXX (relay)

1

as word device

EXXXX (self-diagnosis)

2

bXXXX (timer counter)

3

Fn

(file register)

7

*

1