Communication Setting

The recommended communication parameter setting of both PLC and POD is as follows:

Available Memory

Only D register is available for this PLC model.

No other devices can be used although they are available to be set in theUG00S-

CW.

Set the memory to the extent of the memory range of each PLC model.

Use TYPE number to assign indirect memory for macro programs.

19200bps

Even

7 (ASCII)

Baud Rate

Parity

Transmission

Code

Data Length

Stop Bit

1

Sum Check

Item

Setting of PLC

19200bps

Even

7

1

Comm. Parameter of POD

Provided (fixed)

RS-232C [Wiring Diagram 1]

PLC

SELMART-100 or later series

Select PLC Type

SELMART

Version O1M2-UCI-6x

Wiring Diagram

Link Unit

38 Shinko PLC

Memory

TYPE

Remarks

D

(data register)

0