17 hitachi plc . 1, Hitachi plc • 1 -48, Hitachi plc • 1 – Fujitronic Programmable Operation Display UG520H-x User Manual

Page 117: Hidic h series), Available plc, Communication setting

Advertising
background image

2 - 48

HITACHI PLC • 1

(HIDIC H series)

17

Available PLC

*

1 When using [EH-RS05] cable made by HITACHI, connect the cable of [Wiring Diagram 1] to the

D-sub 15 pins side of [EH-RS05] to communicate with POD.

*

2 When using [CNCOM-05] cable made by HITACHI, connect the cable of [Wiring Diagram 1] to

the D-sub 15 pins side of [CNCOM-05] to communicate with POD.

Communication Setting

The recommended communication parameter setting of both PLC and POD is as follows:

COMM-2H

If “Transmission control mode” is any other type except the above, specify “Transmission control

code” as below.

*

1

Cannot be connected to POD by multi-link connection.

CPU module

Peripheral port is only available with “pattern 1.”

Port

Transmission
Control Mode

RS-232C

RS-422

MODE7

MODE9

Protocol 2 w/ Port

Protocol 2 w/ Port

19200bps

Even

7 (ASCII)

Baud Rate

Parity

Transmission

Code

Data Length

Stop Bit

1

Sumcheck

Item

Setting of PLC

0

19200bps

Even

7

1

*

1

0 for both STATION 10 and 1

Comm. Parameter of POD

Provided (fixed)

Transmission
Control Mode

RS-232C

RS-422

MODE1
MODE2
MODE9

MODE2

Protocol 1 w/ Port

Protocol 1 w/o Port
Protocol 1 w/ Port
Protocol 2 w/o Port

Setting of PLC

*

1

Comm. Parameter of POD

PLC

Link Unit

Wiring Diagram

HIDIC H series CPU

RS-232C [Wiring Diagram 1]

RS-232C [Wiring Diagram 1]
RS-422 [Wiring Diagram 2]

COMM-2H

PERIPHERAL port
on a CPU module

Select PLC Type

HIDIC-H

*

1 [EH-RS05] cable made by HITACHI

+ RS-232C [Wiring Diagram 1]

EH150

PERIPHERAL 1
RS-232C [Wiring Diagram 1]
PERIPHERAL 2

*

2 [CNCOM-05] cable made by HITACHI

+ RS-232C [Wiring Diagram 1]

H-252C on a CPU module

17 HITACHI PLC

1

Advertising