Fujitronic Programmable Operation Display UG520H-x User Manual

Page 228

Advertising
background image

3 - 14

5 Connecting Communication Interface

Mounting the I/F unit(UG03I-x)

•

Remove the seal for preventing dust attached on the back of the POD as shown in the figure on the right.

Mount the I/F unit, then secure it using the 3 screws.

•

Route the communication cable. For details regarding how to lay and connect the communication cable,

refer to the corresponding user’s manual.

•

For the UG320/UG221, set the spacer contained in the package to the hole on the upper left side, then

mount the I/F unit.

CN2

MJ1

MJ2

CN

1

100-

240VAC

L

N

NC

Mounting screws (3 positions)

*

POD

I/F unit

POD

I/F unit

MJ2 MJ1

CN2

CN1

DC24V

(+)

(-)

Mounting screws
(4 positions)

*

I/F unit

Notch

*

Tightening screws for fixing a unit

See the table below for how to tighten the screw for fixing a unit:

Type of screw

Screw size

Tightening torque (N•m)

Unit mounting screw

M3

0.3 to 0.5

Mounting the I/F unit(UG02I-x)

•

Route the insulated cable through the

notch.

•

Remove the seal for preventing dust

attached on the back of the POD as shown

in the figure on the right.

Mount the I/F

unit, then secure it using the 4 screws.

•

Connect the insulated cable with

the ground terminal on the POD.

•

Route the communication cable.

For details regarding how to lay

and connect the communication

cable, refer to the corresponding

user’s manual.

*

Tightening screws for fixing a unit

See the table below for how to tighten the screw for fixing a unit:

Type of screw

Screw size

Tightening torque (N•m)

Unit mounting screw

M3

0.3 to 0.5